Products › Power & Rack Equipment
APC Symmetra LX 16kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V
Part number SYAF16KXR9I
SYMMETRA LX 16KVA N+1 EXT. RUN -WER FRAME 220/230/240V
- 16 kVA 12800 W
- Sealed Lead Acid (VRLA)
- Black
- Manufacturer
- APC BY SCHNEIDER ELECTRIC
- Part number
- SYAF16KXR9I
- Condition
- New
- Category
- Power & Rack Equipment › Power Equipment
- 1GPA category
- Hardware
Overview
APC Symmetra, 12.8 kW / 16 kVA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model
Includes: CD with software, Documentation CD, Installation guide, User Manual, Web/SNMP Management Card
SYA16K16PXR Features
Shippable with modules installed
Enables pre-installation UPS staging and testing and faster installation.
Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.
Availability:
Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Scalability:
Scalable power capacity
Specifications
| Output power capacity | 16 kVA |
|---|---|
| Output power | 12800 W |
| Emergency Power Off (EPO) | Yes |
| Noise level | 62 dB |
| Audible alarm(s) | Yes |
| Serial ports quantity | 1 |
|---|
| Battery technology | Sealed Lead Acid (VRLA) |
|---|---|
| Battery recharge time | 7.5 h |
| Replacement battery cartridge | 9 |
| Product colour | Black |
|---|
| Operating temperature (T-T) | 0 - 40 °C |
|---|---|
| Storage temperature (T-T) | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 4500 m |
| Width | 599 mm |
|---|---|
| Depth | 997 mm |
| Height | 1880 mm |
| Weight | 503.6 kg |
| Package weight | 535.5 kg |
|---|
| Battery type | SYBT5 |
|---|---|
| Output connections | 2PH+N+G |
| Output voltage note | 120/208V, 120/240V |
| Communication options, cards | AP9619 |
| Communication options, slot | Smart-Slot |
| Package dimensions (WxDxH) | 599 x 997 x 1880 mm |
Product photos and overview provided by the manufacturer through Icecat. Confirm specifications with your rep before ordering.