Serving Arizona school districts since 1999 480-460-5199 info@needthese.com
NeedThese, Your Tech-ucation Partner Your quote

Products › Power & Rack Equipment

APC BY SCHNEIDER ELECTRIC

APC NetShelter Switched Rack PDU, 9K series, 0U, 8.6kW, 208V, 21 C13 and C15, 3 C19 and C21 outlets

Part number APDU9965

RACK PDU 9000 SWITCHED ZEROU 8.6KW 208V 21 C13 3 C19

  • Switched 0U Black
  • 24 AC outlet(s) C13 coupler, C15 coupler, C19 coupler, C21 coupler
  • 8600 W
Manufacturer
APC BY SCHNEIDER ELECTRIC
Part number
APDU9965
Condition
New
Category
Power & Rack Equipment › Rack Equipment
1GPA category
Hardware

Overview

Field-replaceable NMC

Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.

High Retention Outlets

With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.

60C Operating Temperature

Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).

C13/C15 and C19/C21 Hybrid Outlets

Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.

Hydraulic Magnetic Circuit Breakers

Provide increased availability by maintaining trip current over a wide temperature range.

Specifications

Design
PDU typesSwitched
Rack capacity0U
MountingVertical
Product colourBlack
Ports & interfaces
AC outlets quantity24 AC outlet(s)
Power plugNEMA L21-30P
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Features
Cable length1.8 m
Power
Nominal input voltage208 V
Maximum current30 A
Output voltage208 V
Load capacity8600 VA
Maximum power8600 W
Certificates
CertificationCULus, FCC 15 A, ICES-003
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Operating altitude0 - 3048 m
Non-operating altitude0 - 15240 m
Weight & dimensions
Width56 mm
Depth51 mm
Height1829 mm
Weight8.18 kg
Packaging data
Package weight10.3 kg
Package width165 mm
Package depth124 mm
Package height2040 mm