Serving Arizona school districts since 1999 480-460-5199 info@needthese.com
NeedThese, Your Tech-ucation Partner Your quote

Products › Power & Rack Equipment

APC BY SCHNEIDER ELECTRIC

APC Rack PDU 9000 Switched, ZeroU, 16A, 100-240V, (21) C13/C15 & (3) C19/C21, Japan

Part number APDU9959J

NETSHELTER RACK PDU 9000 SWITCHED ZEROU 16A 100-240V 21 C13

Manufacturer
APC BY SCHNEIDER ELECTRIC
Part number
APDU9959J
Condition
New
Category
Power & Rack Equipment › Rack Equipment
1GPA category
Hardware

Overview

Field-replaceable NMC

Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.

High Retention Outlets

With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.

60C Operating Temperature

Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).

C13/C15 and C19/C21 Hybrid Outlets

Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.

Hydraulic Magnetic Circuit Breakers

Provide increased availability by maintaining trip current over a wide temperature range.

Specifications

Design
PDU typesSwitched
Rack capacity0U
MountingVertical
Product colourBlack
Ports & interfaces
AC outlets quantity24 AC outlet(s)
Power plugNEMA L6-20P
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power
Nominal input voltage200 V
AC input frequency50 - 60 Hz
Maximum current16 A
Nominal output voltage200 V
Output voltage200 V
Load capacity3300 VA
Certificates
Compliance certificatesRoHS
CertificationFCC 15 A, PSE
Sustainability
Sustainability complianceYes
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Operating altitude0 - 3048 m
Non-operating altitude0 - 15240 m
Weight & dimensions
Width55 mm
Depth46 mm
Height1797 mm
Weight5.55 kg
Packaging data
Package weight7.86 kg
Package width165 mm
Package depth114 mm
Package height2002 mm
Logistics data
Warranty period3 year(s)

Product photos and overview provided by the manufacturer through Icecat. Confirm specifications with your rep before ordering.